Design & Construct of retention system, comprising CFA secant pile wall paired with ground anchors
Construction of fully tanked basement using a 5,000M2 fully-welded PVC waterproof membrane required new techniques and methodologies; PVC waterproof membrane also acted as a vapour barrier
Key Challenges
Works undertaken during one of highest local rainfall periods on record
Construction of waterproof retention walls and basement hydrostatic slab, with full FRP package for all structural elements
Complex works programme (and design elements) successfully executed in regional location while achieving site specific local labour and social procurement targets